Age-related Changes in Anterior Segment Biometric Measurements in New Zealand White Rabbits

Poster Authors:
Sudan Puri; Vivian Trenti; James Lee; Marcela Duran; Walter Collette; Sujata Rijal; Hannah Gill; Jenny Walters; Yesica Chaparro; Stephanie Peters; Xiaohui Zhang; Sara Mangosing; Matthew Lyulkin; Sandeep Kumar; Glenwood G Gum
Ophthalmology, Pharmaron US Lab Services, San Diego, CA, United States
This study investigates how age impacts key anterior segment biometry in New Zealand White (NZW) rabbits, a commonly used model for preclinical ocular research.
Highlights from our anterior segment biometry poster:
- Corneal differences: Younger rabbits had thinner corneas and steeper curvature compared to older rabbits.
- Intraocular pressure: Higher in young rabbits (20.11 mmHg) versus older ones (18.19 mmHg).
- Anterior chamber volume: Significantly larger in older rabbits, while chamber depth remained similar across groups.
- Endothelial cells: No significant age-related differences in cell size or density.
These findings highlight the importance of age when designing and interpreting ocular device studies in NZW rabbits.